Square mesh: SL62 to SL102
Square mesh has the same wire both ways at 200 mm centres. InfraBuild lists it for house slabs, driveways, patios and other pavements. In the code, the first number is the wire size rounded and the last is the spacing in hundreds of millimetres: SL82 is 7.6 mm wire at 200 mm, and SL81 is the same wire at 100 mm.
| Mesh | Wire, each way | ARC sheet, kg | InfraBuild sheet, kg |
|---|---|---|---|
| SL62 | 6 mm at 200 | 33 | 33 |
| SL72 | 6.75 mm at 200 | 40 | 41 |
| SL82 | 7.6 mm at 200 | 52 | 52 |
| SL92 | 8.55 mm (ARC) or 8.6 mm (InfraBuild) at 200 | 65 | 66 |
| SL102 | 9.5 mm at 200 | 80 | 80 |
| SL81 | 7.6 mm at 100 | 105 | 105 |
Ute sheets
For a small slab, or to carry mesh on a ute without overhang, SL62, SL72 and SL82 also come in 4.0 × 2.0 m sheets: ARC calls them 4B2, InfraBuild UTEMESH. They weigh 18, 23 and 30 kg, so one person can handle them.
Rectangular mesh: RL718 to RL1218
Rectangular mesh has heavier main wires at 100 mm one way and 7.6 mm cross wires at 200 mm the other. InfraBuild lists it for pavements, floors, precast panels and suspended floors. The slab tables in the NCC’s Housing Provisions call for square mesh.
| Mesh | Main wires at 100 | ARC sheet, kg | InfraBuild sheet, kg |
|---|---|---|---|
| RL718 | 6.75 mm | 68 | 67 |
| RL818 | 7.6 mm | 79 | 79 |
| RL918 | 8.55 mm (ARC) or 8.6 mm (InfraBuild) | 93 | 93 |
| RL1018 | 9.5 mm | 109 | 109 |
| RL1118 | 10.65 mm (ARC) or 10.7 mm (InfraBuild) | 131 | 130 |
| RL1218 | 11.9 mm | 157 | 157 |
Trench mesh
Trench mesh is a strip of 3 to 5 wires at 100 mm, 6 m long, for the bottom of strip footings and slab beams. The code gives the wire and the number of wires: 3-L11TM is three 10.7 mm wires, 200 mm wide.
| Trench mesh | Wire | Width | Mass, kg (InfraBuild) |
|---|---|---|---|
| 3-L8TM / 4-L8TM / 5-L8TM | 7.6 mm | 200 / 300 / 400 mm | 6.8 / 9.2 / 11.6 |
| 3-L11TM / 4-L11TM / 5-L11TM | 10.7 mm | 200 / 300 / 400 mm | 13.3 / 17.7 / 22.3 |
| 3-L12TM / 4-L12TM / 5-L12TM | 11.9 mm | 200 / 300 / 400 mm | 15.8 / 21.2 / 26.5 |
To count it, ARC divides the beam length by 5.4 and rounds up, then multiplies by the number of layers: a 24 m beam takes 5 lengths a layer. Trench mesh laps 500 mm at a splice and runs the full width across a T or L junction (NCC Table 4.2.11b).
Which mesh a house slab needs
Under the NCC’s Housing Provisions, a stiffened raft slab on a Class A or S site takes SL72 for most wall types, and SL82 under full masonry on a Class S site. On a Class M site it goes up to SL82 under articulated full masonry and SL92 under full masonry (Tables 4.2.14a to c). Where tiles or another brittle floor will cover more than 16 m², NCC 4.2.19 asks for SL92 in that area, or one of its other options. The concrete slab calculator has the full table, with beam depths.
The NCC also lets bars stand in for trench mesh (Table 4.2.11a): 3-L11TM can be 3 N12 bars, for example, and 2-L11TM can be one N16 or two N12.
Laps and bar chairs
- Laps: square and rectangular mesh sheets overlap so the two outermost cross wires of one sheet sit over the two outermost wires of the next (NCC 4.2.11).
- Cover: at least 40 mm to the ground or outside, 30 mm to a membrane, 20 mm to an inside surface.
- Bar chairs: no more than 800 mm apart under mesh. InfraBuild’s rule of thumb is slab area ÷ 0.56.
- How many sheets: ARC divides the slab area by 12.4, InfraBuild by 12.5, and rounds up. That reuses offcuts, so a long, narrow slab can need more.
From materials to a price
Deftara Quoting prices a square metre of slab once, as a kit of concrete, mesh, chairs, film and labour, so every quote prices itself from the area and your own costs. Then check your markup and margin.
More for trades
The concrete slab calculator works out the concrete, mesh, chairs and film for a slab, the brick calculator counts bricks and mortar, and the trade tools page has the rest.
Sources
- ARC: square reinforcing mesh (wires and masses), checked 2 November 2026.
- ARC: national product catalogue, February 2013 (6.0 × 2.4 m and 4.0 × 2.0 m sheets, rectangular and trench mesh, the counting rules), checked 2 November 2026.
- InfraBuild Reinforcing: product guide, 4th edition (ONEMESH square, rectangular, UTEMESH and trench mesh, bar chairs), checked 2 November 2026.
- NCC 2025 ABCB Housing Provisions, Part 4.2 (4.2.11, Tables 4.2.11a and b, 4.2.14a to c, 4.2.19), checked 2 November 2026; the same in NCC 2022.