The NCC stair rules for houses
These are the deemed-to-satisfy figures in the ABCB Housing Provisions, Part 11.2. They’re the same in NCC 2022 and NCC 2025, so they hold whichever edition your state is on.
| The stair serves | Riser (R) | Going (G) | 2R + G |
|---|---|---|---|
| Living areas, bedrooms, decks (Table 11.2.2a) | 115 to 190 mm | 240 to 355 mm | 550 to 700 mm |
| Only attics, storerooms and rooms not used every day (Table 11.2.2b) | 130 to 225 mm | 215 to 355 mm | 540 to 700 mm |
The rest of clause 11.2.2 and the parts that go with it:
- 2 to 18 risers in each flight. More than 18 needs a landing, and landings must be at least 750 mm long, no steeper than 1:50.
- Constant risers and goings. Adjacent risers, or adjacent goings, can differ by 5 mm at most, and the largest and smallest in a flight by 10 mm.
- Open risers can’t leave a gap a 125 mm sphere passes through. The gap is about the riser less the tread’s thickness, so a 175 mm riser needs treads 50 mm thick or a riser bar. Stairs serving only attics or storerooms are exempt.
- Handrail along at least one side for the full flight, its top at least 865 mm above the nosings, once the stair changes level by 1 m or more (11.3.5).
- Barrier where someone could fall 1 m or more: at least 865 mm above the nosings on the flight and 1 m on landings (11.3.3 and 11.3.4). Gaps, edges and climbing: our balustrade and handrail rules.
Your plans or your certifier have the final say. This page is a guide to the figures, not an approval.
How it works out the stair
- Floor to floor divided by the riser you aim for, rounded to whole risers. If that riser is over 190 mm it adds one; under 115 mm, it takes one off.
- Riser height is floor to floor divided by the number of risers. The going is the tread depth from one nosing to the next.
- Treads are one fewer than risers, because the upper floor is the top step.
- Total run is treads times the going.
- The stringer along the nosing line is √(rise² + run²). Allow 300 mm for the top and bottom cuts and buy the next length up in 300 mm steps.
When you mark out a cut stringer with treads sitting on top, drop the bottom cut by one tread thickness. Otherwise the first step comes out a tread thickness higher than the rest, and the risers are no longer constant.
A worked example
A stair between two floors 2,800 mm apart, with 250 mm goings, aiming for a 175 mm riser:
- 2,800 ÷ 175 is exactly 16 risers of 175 mm, and 15 treads.
- 15 treads at 250 mm is a 3,750 mm run, at an angle of 35°.
- 2R + G is 2 × 175 + 250 = 600 mm, inside 550 to 700.
- The stringer is √(2,800² + 3,750²) = 4,680 mm. With 300 mm for the cuts, buy 5.1 m lengths.
- It rises more than 1 m, so it needs a handrail, and a barrier on any open side.
Deck stairs
Measure the rise from the deck to the finished ground or pad where the stair lands, not at the deck’s edge: ground that falls away adds to the rise. A deck 900 mm up takes 5 risers of 180 mm and 4 treads, a 1,000 mm run at 250 mm goings. Under 1 m of rise, the NCC asks for no handrail. Then work out the deck itself with the decking calculator.
From stair to price
That’s the job Deftara Quoting does for carpenters: stringers and treads by the metre and fixings as items, built once as a kit and priced from your own timber list. Then check your markup and margin.
More for trades
- Decking calculatorLineal metres of board with gaps and waste, joists at your spacing, and screws.
- Fence calculatorPosts, rails, palings or Colorbond panels, and bags of concrete.
- Free quote templatesWord, Excel and PDF, with a carpentry version that prices timber by length.
Sources
- NCC 2025, ABCB Housing Provisions Part 11.2: clause 11.2.2 and Tables 11.2.2a and 11.2.2b. Checked 31 October 2026.
- NCC 2022, ABCB Housing Provisions Part 11.2: the same tables, and clause 11.2.5 (landings). Checked 31 October 2026.
- NCC 2022, ABCB Housing Provisions Part 11.3: clauses 11.3.3, 11.3.4 and 11.3.5 (barriers and handrails). Checked 31 October 2026.